If the pressure in the tank exceeds 150 psi or the temperature exceeds 210 degrees fahrenheit the tpr valve opens to release the pressure.
Hot water heater discharge pipe code.
Not be directly connected to the drainage system.
Summary of relief valve code requirements.
The plumbing code can be a little confusing if your not a plumber.
A trapped tpr dischage pipe is a common defect when a replacement water heater s tpr valve is lower than the original one and the installer connects to the exisitng discharge piping at the wall.
Scalding water and steam escape the tank through the valve and tube to relieve the pressure.
504 6 requirements for water heater tpr valve discharge piping the discharge piping serving a pressure relief valve temperature relief valve or combination thereof shall.
8 termination of the tpr drain pipe cannot be more than 6 inches or less than two pipe diameters above the floor ground or waster receptor.
Installing a tank water heater might seem easy but homeowners who refinish their basements often create a number of code violations with respect to the water heater.
2017 fbc residential 6 th edition 28 water heaters p2804 relief valves p2804 6 installation of relief valves p2804 6 1 requirements for discharge pipe 1114 1 4 storm drainage piping discharge piping shall meet the requirements of section 1102 2 1102 3 or 1102 4 and shall include a gate valve and a full flow check valve.