It is important for the fireplace opening to match the chimney size.
Gas fire chimney flue regulations.
1 no person shall install a gas appliance to any flue unless the flue is suitable and in a proper condition for the safe operation of the appliance.
Flue gases from the stove must be able to discharge freely without presenting a fire or health hazard whatever the wind conditions.
The throat of the chimney where the smoke chamber tapers to the size of the flue should be no less than 8 inches above the firebox and should be at least 4 inches deep.
Be not less than 1 7 th to 1 8 th of the area of the fireplace opening if the flue or chimney height is above 6 metres.
The distance between the cowl of the flue and the adjacent roof wall structure should be higher than 2 3 mtr.
This is for masonry chimneys.
Standard for chimneys fireplaces vents and solid fuel burning appliances nfpa 211 reduces fire hazards by ensuring the safe removal of flue gases the proper installation of solid fuel burning appliances and the correct construction and installation of chimneys fireplaces and venting systems.
Your firebox wall needs to be 8 inches thick when lined with fire bricks or 10 inches thick without fire bricks.
The icc though suggests at least 12 inches.
Minimum clearance distance requirements for the exterior vent termination of a gas fireplace heater 8.
A vertical line drawn along the up roof side of the chimney from the roof surface to the top of the chimney flue opening shall be at least 3 ft in height.
As a rule of thumb the chimney fireplace opening should.
A 225mm diameter flue of a similar height will support a fireplace with a dimension no greater than 550mm by 550 mm 22inches by 22 inches.
For a gas vent or type l vent this height must be 2 ft 0 61m or more.
The top of the flue opening should be 3 ft 0 92 m above any roof surface.
Cross sectional areas of clay flue linings are shown in tables r1003 14 1 and r1003 14 2 or as provided by the manufacturer or as measured in the field.
Direct vent gas fireplace exhaust termination item clearance distance.
A flue size providing not less than the equivalent net cross sectional area shall be used.
This means that the flue outlet needs to be positioned sufficiently high above the roof surface and surrounding buildings to prevent it being affected by wind eddies or downdraughts.
2 no person shall install a flue pipe so.
The height of the chimney shall be measured from the firebox floor to the top of the chimney flue.
Clearance above paved sidewalk or a paved driveway located on public property.